
Quick Specs
Swipe to compare all columns.
| Comparison input | Volumetric filling | Net-weight filling |
|---|---|---|
| Quantity the filler controls | A predetermined volume | Measured product weight |
| What the dose is measured by | Not measured as mass | A scale or load cells |
| Starting point in public descriptions | Sold by volume; density (and a liquid's viscosity) consistent | Density varies, or sold by weight |
| Effect of a density change | Changes the mass of the fixed volume | Does not by itself change the mass setpoint |
| Reading it in the other unit | Needs density and temperature to check on a scale | Needs density to express as a volume |
| Record before comparing | Same product, batch, pack, point and time | Same product, batch, pack, point and time |
What each method controls
Comparing the two methods on the wrong quantity leaves you with no usable answer: a millilitre target set against a gram reading, with no density written down, says nothing about which filler suits your product. Volumetric filling dispenses a predetermined volume, and that action does not measure the dose as mass. Net-weight filling controls the dose by the measured weight of product, using a scale or load cells, rather than by volume or by time.
Public filling-equipment descriptions offer a starting point, not a ranking. Start with volume control when the quantity you sell is a volume and the product's density stays consistent; for a liquid, its viscosity should stay consistent as well. Start with weight control when the density varies or when the quantity you sell is a weight. We compiled that split from public equipment descriptions. It is not the result of a test on this site, and it does not say that either method is better.
That makes the first decision a question about your own product rather than about machines: which quantity must the filler control, and which quantity will someone check afterwards? The two are often different. A volume target can be checked on a scale, and a weight target can be checked against a volume measure, but each crossover needs the product's density and the conditions it was measured under. The rest of this page gives you one record that holds those inputs together, a unit check that links mass and volume, and the points where the two records still diverge.
Quick record: what to write down
Before either method is compared, put the inputs for one condition side by side. The table lists every field on the record, what to enter in it and why the field changes the comparison. The cells are instructions, not typical values. Where you have no reading, write "not measured" instead of an estimate, because an estimated density or tare looks like data once it sits in a column.
Two fields carry more weight than the rest. The target unit tells you whether the sold quantity is a mass or a volume, and so which way the conditional start points. The measurement point and time tell you whether two readings belong to the same condition at all. Without them, a tare taken on one pack in the morning and a gross reading taken on another pack later in the day can be subtracted as if they described one fill.
| Input | What to write down | Why it changes the comparison |
|---|---|---|
| Product | Name and form of the product as it is filled | A density belongs to one product, not to a product category |
| Batch | Batch or lot code | Keeps every reading on one lot |
| Measurement temperature and method | Temperature, plus the balance, cylinder or other method used | A density or volume reading belongs to the conditions it was taken under |
| Target quantity | The number set as the fill target | The reference both records are read against |
| Target unit (mass or volume) | g, kg, mL or L, written beside the number | Shows whether the sold quantity is a mass or a volume |
| Density and units, if measured | Value with its unit, such as g/mL, or "not measured" | Needed to convert between mass and volume |
| Empty-pack tare | Mass of the empty pack, with its unit | Subtracted from gross mass to give net mass |
| Gross mass | Mass of the filled pack on the same scale | The reading net mass is calculated from |
| Net mass | Gross mass minus tare, in the same unit | Usable only when tare and gross share the scale, pack, point and time |
| Volume measurement method | How the volume was measured, for example a cylinder | Separates a volume dose from a mass check |
| Actual quantity | The measured quantity, with its unit | Shows what was filled, as distinct from what was set |
| Measurement point and time | Where and when the readings were taken | Stops two conditions being compared as one |
Blank same-condition record
Use the blank record below to collect one condition at a time. Keep each row to one product, one batch, one pack and one measurement point and time. If any of those four changes, start a new row instead of editing the old one. A row that mixes two batches or two packs cannot be read against either method, because you no longer know which density or which tare belongs to the reading.
Fill in the target quantity and target unit before any reading is taken, so the record shows what was intended and not what was found. Then record the empty-pack tare, the gross mass and the net mass on the same scale, and the volume measurement method with its actual quantity. Leave a field empty when you have no reading for it. An empty cell tells the next person what is missing; a guessed value hides it.
If you are comparing a volume-controlled fill with a weight-controlled fill, keep one row per method under the same product, batch and pack, and give each row its own measurement point and time. The record does not score either row. It only makes sure that the two rows describe the same thing before anyone reads a difference into them.
| Product | Batch | Measurement temperature and method | Target quantity | Target unit (mass or volume) | Density and units, if measured | Empty-pack tare | Gross mass | Net mass | Volume measurement method | Actual quantity | Measurement point and time |
|---|---|---|---|---|---|---|---|---|---|---|---|

Unit check: mass = density × volume
A fixed volume equals a given mass only through mass = density × volume, and only after the units are written in. Do not treat 1 g as 1 mL. The identity is arithmetic, not a machine measurement: it tells you what a reading should be in the other unit, given the density you wrote down. It does not tell you what a filler delivered.
On the record, net mass is gross mass minus empty-pack tare, and only when both readings come from the same scale, the same pack and the same measurement point and time. That is a rule for filling in the sheet, not a description of how any filler works. If the tare came from a different pack, or from the same pack on another scale, the subtraction mixes two conditions, and the net mass it produces should not be compared with anything.
Here is one walk-through with assumed inputs only. Assume a target of 500 mL, a density of 1.10 g/mL measured at an assumed 20 °C, an empty-pack tare of 30.0 g and a gross mass of 580.0 g, both on the same scale and pack. Net mass is 580.0 g − 30.0 g = 550.0 g. The mass expected for 500 mL at the assumed density is 1.10 g/mL × 500 mL = 550 g. Both results are arithmetic on assumed values. They are not a fill that a machine achieved, a typical density or an acceptance limit.
The same assumed numbers show why the unit matters. Had the target been written as a bare 500 and read as 500 g, the record would show a 50 g gap that comes entirely from the units, not from either filling method. Writing g or mL beside every number, and g/mL beside the density, keeps that gap out of the comparison.
A volume target that is checked on a scale still needs the density and the temperature written down beside the reading. The density converts the mass back to a volume; the temperature and method tell the next reader which density applies. If the density field says "not measured", the scale reading stays a mass and the volume target stays unchecked.
What still makes the two records diverge
Even with a clean record, the volume and the mass of the same fill can tell different stories. The same dispensed volume can look uneven when container dimensions differ, so a row of fills at different heights is not, on its own, evidence that the volumes differed. Record the pack with each row and compare fill levels only within the same pack.
Density is the second source. A change in density changes the mass of a fixed volume; it does not by itself change a mass setpoint. A volume-controlled fill and a weight-controlled fill of a product whose density has shifted will therefore move apart on the record even when both run as set: one holds its volume and changes in mass, while the other is still set to the same mass.
Terms are the third. "Fill weight" and "net weight" are not automatically the same term. A net-weight filler controls the weight of product in the container; a volumetric filler controls volume. Before you compare two records, confirm what each label on them means for your product, and which one is the quantity you sell. This page does not name a winner. The record shows which quantity your product needs the filler to control, and the comparison holds only for the condition written on that row.

What this page does not decide
This comparison covers which quantity a filler controls and how to record the inputs that link mass and volume. It does not compare dosing mechanisms such as an auger and a volumetric cup, and it does not choose a machine family for your product. Those choices depend on how the product behaves inside a machine, which the record above does not capture.
It also leaves out line effectiveness, lane-by-lane sampling and acceptance trials, and it gives no advice on compliance with any labelling or metrology rule. Once you have the density, tare and fill record, the guide on agreeing how net quantity is measured is where a quoted figure is tied to a target dose, a sample and a count window. Take your record into that step rather than replacing it.
What to send us
Send that record, including "not measured" where a field is unknown, through the Request a Quote page. The reply says whether your target is a mass or a volume and which field is still missing before the two methods can be compared. We reply within 24 hours.
The table below lists each item, why we need it and a format that keeps the units visible. The reply covers the record only. It does not propose a machine model, a price, an accuracy figure or a sample test.
Method and sources
Compiled from public filling-equipment descriptions fetched on 6 October 2026 and 8 October 2026. The definitions of volumetric and net-weight filling, the note that fill weight and net weight are not automatically the same term, the conditional starting point and the caveat about container dimensions come from those descriptions. They are descriptions, not test results, and this page reports no test of either method.
The same-condition record, the unit check and the walk-through are our editorial method. Every number in the walk-through is assumed and labelled as such. The page contains no machine speed, accuracy figure, price or customer result, because none of the descriptions we read supported one for a general comparison.
Common questions
Is fill weight the same as net weight?
Not automatically. A net-weight filler controls the weight of product in the container, while a volumetric filler controls volume, and a label that says "fill weight" does not tell you which of those was controlled. Check how each term is defined for your product, and record empty-pack tare and gross mass separately so net mass can be calculated on the same scale.
What is the difference between filling by weight and filling by volume?
Filling by volume dispenses a predetermined volume and does not measure the dose as mass. Filling by weight controls the dose by the measured weight of product, using a scale or load cells, rather than by volume or by time. Public equipment descriptions point to volume control as a starting point when the product is sold by volume and its density stays consistent, and to weight control when density varies or the product is sold by weight.
What if the product's density has not been measured?
Write "not measured" in the density field and leave the unit check for later. Without a density, a scale reading stays a mass and cannot be read against a volume target, and a volume reading cannot be read against a mass target. The other fields are still worth recording, because they show the target unit and whether the tare and gross readings share one scale, pack and measurement time.
What to send us
Swipe to compare all columns.
| Item | Why we need it | Example format |
|---|---|---|
| Product and batch | Keep the record on one lot | Product name and lot code |
| Target quantity and unit | Shows whether the sold quantity is mass or volume | 500 g or 500 mL, not a bare number |
| Measurement temperature and method | A volume checked on a scale needs the conditions of the density | Temperature plus balance, cylinder, or other method |
| Density and units, if measured | Runs the mass = density × volume check | Value with unit, or "not measured" |
| Empty-pack tare, gross mass, and net mass | Net is usable only when tare and gross share the scale, pack, and time | Three readings with units |
| Volume method and actual quantity | Separates a volume dose from a mass check | Method plus the quantity and unit |
| Measurement point and time | Stops two conditions being compared as one | Where and when the readings were taken |
We reply within 24 hours.